Conduit fitting types explained: straight fittings, Y-fittings and membranes

Industry News admin

Half of a conduit system's protection lives in its fittings. Straight fittings fix and seal conduit to equipment, Y-fittings split one run into two, and membranes keep ducts sealed until pulling. Sizing by thread and diameter, plus three installation checks.

Short answer: the conduit covers only the middle of a run - both ends live or die by the fittings. The IP rating of the whole line is decided at its weakest point, which is usually a fitting. Three common accessory types do three different jobs: straight fittings fix and seal conduit to equipment, Y-fittings split one run into two, and membranes keep ducts sealed until cable pulling.

Straight fittings: the standard conduit-to-equipment joint

A straight fitting is a body plus a locking nut and a sealing ring: the conduit screws into the body, the nut clamps it to the panel cutout, and the ring seals against both the duct wall and the panel - dust and water protection happens right here. Two matches to check: the thread must match the cutout and thread system (metric M, pipe G, or PG), and the diameter range must match the conduit. In the JMYQ range the model number is the diameter: JMYQ0710 fits 7-10 mm, JMYQ1014 fits 10-14 mm - per the original manufacturer data. PA66 nylon is the usual choice indoors; nickel-plated brass suits machine-tool environments with coolants and oils.

Y-fittings: one run into two

When a trunk needs to split (a sensor branch leaving the main run), a Y-fitting merges two conduits into one entry without an extra junction box. Note that each branch carries a smaller duct after the split, so the Y-port diameter range follows the branch diameter, not the trunk - the most common mis-selection.

Membranes: sealed ends, easy pulling

A membrane is the thin film that ships across fittings and duct ends: it keeps dust and water out during transport and storage, then breaks through with a tool when cables are pulled, after which the fitting locks and seals again. Without membranes, open duct ends ingest contamination before pulling - and the IP rating dies at the end. Dead ends that reach no equipment get blind plugs instead.

Three installation checks

1) cut the duct end square and deburred (burrs cut sealing rings and cable jackets); 2) sealing ring present and undamaged, nut tight to feel - not overtightened; 3) pull-and-wiggle test after assembly - any play at the fitting means the IP rating is already lost. The full range lives on the cable protection category page; fitting-to-conduit matching follows the original manufacturer data.

Send the thread system, duct diameters and IP requirement to Juanmu for a complete fitting list.